Type: | SWR/Power meter |
Frequency range: | 1.6-1300 MHz in four ranges with two sensors
1.6-160 MHz (sensor 1) 400-525 MHz (sensor 2) 700-1100 MHz (sensor 2) 1240-1300 MHz (sensor 2) |
Power measure ranges: | 5 W 20 W 200 W |
Insertion loss: | 1.6-160 MHz: <0.2 dB 400-525 MHz: <0.1 dB 700-1100 MHz: <0.15 dB 1240-1300 MHz: <0.2 dB |
Dimensions (W*H*D): | 120*72*85 mm (excluding sensor 2) |
Weight: | 830 gr |
Manufactured: | Japan, 198x-20xx |
Other: |
Accuracy: ±10% of full scale (15% on 5 W range)
Minimum power for accurate SWR measurement is 3 W
2*SO-239 (sensor 1), 2*N-jack (sensor 2)
New price 1987 in the US: $129.00
|